• Kstar UD Series 10-80KVA Online Transformerless Commercial UPS
  • Kstar UD Series 10-80KVA Online Transformerless Commercial UPS

Kstar UD Series 10-80KVA Online Transformerless Commercial UPS

Phase: Single Phase
Type: On-line
Protection: Overvoltage
Application: Communication
Classification: Lighting/Power
Standby Time: Long-acting Machine
Customization:
Gold Member Since 2020

Suppliers with verified business licenses

Rating: 5.0/5
Hubei, China
to see all verified strength labels (15)

Basic Info.

Model NO.
Kstar UD
Standby UPS
Square Wave Output UPS
Output Capacity
Large Type
Equipment Mode
Decentralized
Brand
Kstar
Warranty
1 Year
Transport Package
Wooden Cases
Specification
Brand new
Trademark
Kstar
Origin
China
HS Code
8504402000
Production Capacity
1000set/Month

Product Description

Kstar UD Series 10-80KVA Online Transformerless Commercial UPS
 

Specifications
 
MODEL  UD10 / UD10L UD15 / UD15L UD20 / UD20L UD30 / UD30L UD40L UD60L UD80L
Capacity (VA/Watts) 10K / 9K 15K / 13.5K 20K / 18K 30K / 27K 40K / 36K 60K / 54K 80K / 72K
INPUT  
Nominal Voltage 380/400/415Vac(3Ph+N+PE)
Operating Voltage Range 208~478Vac@half load; 305~478Vac@full load
Operating Frequency Range 50Hz:45~55Hz,60Hz:54~66Hz
Power Factor ≥0.99
  Max.voltage: 220V:+25%(Optional +10%,+15%,+20% )
Bypass Voltage Range 230V:+20%(Optional +10%,+15%)
  240V:+15%(Optional +10% )
  Min. voltage: -45% (Optional -10%, -20%,-30%)
ECO Range Same as bypass
Harmonic Distortion (THDi) ≤3%(100% non-linear load)
OUTPUT  
Output Voltage 380/400/415Vac(3Ph+N+PE)
Power Factor 0.9
Voltage Regulation ±1%
Frequency Line Mode ±1%/±2%/±4%/±5%/±10% of the rated frequency(Optional)
Bat. Mode 50/60(1±0.1%)Hz
Crest Factor 3:01
Harmonic Distortion (THDv) ≤2% with linear load
≤5% with non-linear load
Waveform Pure Sinewave
Transfer Time Utility to Battery : 0ms; Utility to Bypass: 0ms
EFFICIENCY  
Efficiency 95%
BATTERY  
Battery Standard unit ±120Vdc (20pcs 12V9AH) ±120Vdc (2x20pcs 12V9AH) ±120Vdc (3x20pcs 12V9AH) N/A
Voltage Long run unit Selectable Voltage:±96V/±108V/±120Vdc Selectable Voltage:±192V/±204V/±216V/ ±228V/±240Vdc
Charging Standard unit 1.35 2.7 4.05 N/A
Current (A) Long run unit Max.current 10A Max.current 15A Max.current 30A
PROTECTI ON  
  Line Mode Load≤110%: last 60min, ≤125%: last 10min, ≤150%: last 1min, ≥150% turn to bypass mode immediately
Overload Bat. Mode Load≤110%: last 10min, ≤125%: last 1min, ≤150%: last 5S, ≥150% shut down UPS immediately
  Bypass Mode 20A(Input breaker) 32A(Input breaker) 40A(Input breaker) 63A(Input breaker) 80A(Input breaker) 100A(Input breaker) 125A(Input breaker)
Short Circuit Hold Whole System
Overheat Line Mode: Switch to Bypass; Backup Mode: Shut down UPS immediately
Battery Low Alarm and Switch off
INDICATORS  
Audible & Visual Alarms Line Failure, Battery Low, Overload, System Fault
Status LED & LCD Display Line Mode, Backup Mode, Eco Mode, Bypass Mode, Battery Low, Battery Bad, Overload & UPS Fault
Parameters On The LCD Panel Input/Output Voltage, Input/Output Frequency, Load Level, Battery Level, Inner Temperature & Remaining Battery Backup Time
MANAGEMENT  
Communication Interface RS-232,RS-485,USB,Parallel card, SNMP card(Optional), Relay card (Optional),Battery temperature sentor(optional)
ENVIRONMENT  
Operating Temperature 0~40ºC
Storage Temperature -25~55ºC
Humidity Range 0~95% (Non-condensing)
Altitude < 1500m
Noise Level <55dB <58dB <63dB
PHYSICAL  
Dimension W×D×H (mm) 250×828×868 360×828×868
Net Weight (kg) 115/57 170/63 171/64 223/71 73 118 122
STANDARDS  
Noise Suppression Complies with EN62040-2
Safety IEC/EN62040-1,IEC/EN60950-1
EMC IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,
IEC61000-4-5,IEC61000-4-6,IEC61000-4-8
Specifications are subject to change withour notice in advance
 
KSTAR UD series online double conversion UPS System adopts advanced DSP control and N+X redundancy design to enhance the reliability. With high power factor (PF) and ECO mode operation for energy saving, UD series is the cost-effective choice in the industry. It has been widely used for server rooms, personal computers, data warehouses, medical clinics, industrial application and office facilities.


Features
 

True double-conversion

Real-time digital signal processor (DSP) control

N+X parallel redundancy

Selectable quantity of battery for each group:for long run unit

Adjustable charging current via LCD

3-stage charging design optimizes battery performance

ECO mode operation for energy saving

Self-diagnosis at startup

Emergency power off function(EPO)

Maintenance bypass is convenient for maintenance

Generator compatible

Communications:RS-232,USB,SNMP card(Optional), Relay card (Optional)

Cold start





______________________________________________________

Wuhan Unique Mechanical And Electrical Equipment Co., LTD. is a high-tech enterprises with a combination of of science, industry and trade. We mainly engaged in R&D and manufacturing of network center room equipment, such as PDU, ODF, CMA, Fiber Spool Frame, Network Panel, Network Cabinet, OF Jointing Box, Fiber Optic Connector, ADSS Cable, Micro Fiber, Pigtail, Patch Cord, UTP Cable, etc. Provide high level of technical consultation and technical services.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now