Customization: | Available |
---|---|
Phase: | Single Phase |
Type: | On-line |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
UPS2000-G series with a capacity ranging from 6kVA to 20kVA is an online double conversion power system that delivers continuous, high-quality AC power. It is rack/tower convertible and 95% high efficiency helps it get ECA energy saving certification from United Kingdom government and the world's first batch of "Energy Star" certification. It's really a perfect power protection solution for small power scenarios.
Scenarios
• Small and medium-sized enterprises, large enterprise branch offices, bank branches and other small data centers.
• Networks, communications systems, automatic control systems and other precision equipment.
Features
Reliable
• 5kA lightning protection design, reducing lightning-related failure rate.
• Key component failure pre-alarm including fans, batteries, bus capacitors to remind customers to maintain before failure occurs.
• Ultra-wide voltage input range to extend battery service life by effectively reducing times of switchover to battery mode.
Efficiency
•High efficiency at online mode to reduce power loss of UPS and air conditioner: up to 95% for 15/20kVA, 94.5% for 10kVA, 94% for 6kVA.
Simple
• Rack/tower convertible, suitable for different installation scenarios.
• High expandability design: up to four units can be connected in parallel to achieve higher capacity or reliability.
• NetEco network manager, supporting centralized management to all the UPSs.
Specifications
Rated Capacity(kVA/kW) | 6/5.4 | 10/9 | 15/13.5 | 20/18 | ||
Input:Output | 1-in:1-out | 1-in:1-out or 3-in:1-out | 1-in:1-out, 3-in:1-out or 3-in:3-out | |||
Mains Input | Input Wiring | L+N+PE | L+N+PE /3Ph+N+PE | |||
Rated Voltage | L-N: 220/230/240V AC | |||||
Input Voltage Range | L-N: 80-280V AC | |||||
Input Frequency Range | 40-70Hz | |||||
Input Power Factor | 0.99 | |||||
Bypass Input | Rated Voltage | L-N: 220/230/240V AC | ||||
Frequency | 50/60 ± 6Hz | |||||
Battery | Rated Voltage | Standard | 240V DC | - | ||
Long Backup | 192-240V DC | 384-480V DC, 32-40 section adjustable, default 40 | ||||
Output | Output Wiring | L+N+PE | L+N+PE /3Ph+N+PE | |||
Output Sockets | 2 × C13 (10A) | - | ||||
Rated Voltage | 220/230/240V AC ±1% | L-N: 220/230/240V AC ±1% | ||||
Rated Frequency | Tracking the bypass input (Normal mode); 50/60 Hz±0.05% (Battery mode) | |||||
Output Power Factor | 0.9 | |||||
Waveform | Sine wave, THDv<2% | |||||
Efficiency | 94% | 94.5% | 95% | |||
Enviro- nment | Operating Temperature | 0-40ºC | ||||
Storage Temperature | -40 to 70ºC | |||||
Relative Humidity | 0%-95% (No condensing) | |||||
Operating Altitude | 0-1000m. Above 1000m, derating rate based on EN/IEC 62040-3 | |||||
Audible Noise | <55dB | <58dB | ||||
Others | H × W × D (mm) | 86 × 430 × 585 | 130 × 430 × 685 | |||
Weight | 14kg | 16kg | 32kg | |||
Certifications | EN/IEC 62040-1; EN/IEC 62040-2; EN/IEC 62040-3; CE; CB; RoHS, REACH, WEEE, etc | |||||
Communications | USB(optional RS485/Dry contact/SNMP) |
Optional components
Optional component | Mode | Remarks |
SNMP card* | RMS-SNMP01A RMS-SNMP01B | RMS-SNMP01A for 6-20kVA,RMS-SNMP01B for 1-3 kVA |
Modbus card* | RMS-MODBUS01A RMS-MOSBUS01B | RMS-MOSBUS01A for 6-20kVA,RMS-MOSBUS01B for 1-3 kVA |
Dry-contact relay card* | RMS-RELAY01A RMS-RELAY01B | RMS-RELAY01A for 6-20kVA,RMS-RELAY01B for 1-3 kVA |
Wireless modem* | TD-8013 | |
36V DC 2*9 Ah battery module | ESS-36V12-9*2AHBPVBB01 | Built-in 2 group 6 pcs, 9 Ah serial batteries (for 1 kVA) |
72V DC 9 Ah battery module | ESS-72V12-9AHBPVBB01 | Built-in 6 pcs, 9 Ah serial batteries (for 2 kVA) |
96V DC 9 Ah battery module | ESS-96V12-9AHBPVBB02 | Built-in 8 pcs, 9 Ah serial batteries (for 3 kVA) |
240V DC 7 Ah battery module* | ESS-240V12-7AhBPVBA01 | Built-in 20 pcs, 7 Ah BB serial batteries |
240V DC 9 Ah battery module* | ESS-240V12-9AhBPVBA01 | Built-in 20 pcs, 9 Ah BB serial batteries |
36V DC 40 Ah battery box | ESS-36V40Ah(12V)*1-BBNBB | Batteries not included, can add 3 pcs, 40 Ah batteries (for 1 kVA) |
36V DC 65 Ah battery box | ESS-36V65Ah(12V)*1-BBNBB | Batteries not include, can add 3 pcs, 65 Ah batteries (for 1 kVA) |
96V DC 40 Ah battery box | ESS-96V40Ah(12V)*1-BBNBB | Batteries not included, can add 8 pcs, 40 Ah batteries (for 3 kVA) |
20 kVA 3/1 parallel PDU* | PDC-0091V2ACIOA | Suitable for two 6 kVA to 20 kVA parallel systems with 1 ph input and 1 ph output format, or 15/20kVA two parallel systems with 3 ph input and 1 ph output format; total power capacity is not more than 20 kVA. |
20 kVA 3/3 parallel PDU* | PDC-0038V4ACIOA | Suitable for two 15/ 20 kVA parallel systems with 3 ph input and 3 ph output format; total power capacity is not more than 20 kVA. |
6 kVA output isolation transformer* | DGL-6/0.22 | |
10 kVA output isolation transformer* | DGL-10/0.22 | |
63 A battery breaker box* | PDC-0063DC0440BBB | Battery Circuit Breaker Box-63A-3P-440V DC-Over Current Releases |
125 A battery breaker box* | PDU8000-0125DCV8-BXA001 | Battery Circuit Breaker Box-125A-4P-750V DC-Remote Control/Shunt Release |
Battery temperature sensor* | TE820E10B / W103-B02-L1 | Temperature Sensor, -40 ºC to 80 ºC, +-1 ºC |
Temperature & humidity sensor* | WS302M2A-5/RH811AC05D | With SNMP card, Temperature & humidity sensor, 12V DC to 24V DC, 0 ºC to 50 ºC, 0% RH to 100% RH, DS OUTPUT |
Parallel monitor and alarm cable* | UPSCU2KUMC00 | UPS2000 merge cable, 1.5m, D15M, CC8P0.48B(S), D15F |