Part number | 241115.815 |
Model | 220 / 2000 HE WOR |
INPUT DATA | |
Voltage range | 85 - 300 V AC/ DC |
Voltage range (nominal) | 185 - 275 V AC/ DC |
Frequency | 0 - 66 Hz |
Maximum current | 11.9 A RMS |
Power Factor | 0.99 (@ 50-100% load) |
THD (@ 230 VAC) | < 5 % (@ full load) |
Protection | Varistor for transient protection, fuse in both lines, shutdown above 300/ 305 V |
OUTPUT DATA | |
Default voltage | 245.3 V DC |
Voltage range | 178.5 1) - 297 VDC |
# Pb cell supported (1.8 - 2.4 V DC/ cell) | 108 - 122 |
# NiCad cell supported (1.05 - 1.65 V DC/ cell) | 170 - 180 |
Max power, nominal input | 2000 W |
Max power, 85V input | 850 W |
Max current, @220V DC | 9.16 A |
Hold-up time, default voltage and 1500 W load | 20 ms, VOUT > 178 V DC |
Ripple and noise, 30 MHz bandwidth | < 1000 mV PP |
Current sharing | ±5% of maximum current from 10 to 100% load |
Static voltage regulation | ±0.5% from 10% to 100% load and nominal input |
Dynamic voltage regulation | ±5.0% for 10-90% or 90-10% load variation, regulation time < 50ms |
Protection | Overvoltage shutdown, short circuit proof, high temperature, hot plug -in inrush current limiting, ORing diode |
OTHER SPECIFICATIONS | |
Efficiency | > 95% |
Isolation | 3.0 kVAC - input to output, 1.5 kV AC - input to earth, 1.5 kV DC - output to earth 3 kVAC - CAN to input, 3 kV AC - CAN to output, 500 V AC - CAN to earth |
Alarms (Red LED) | Low mains shutdown, High and low temperature shutdown, Rectifier Failure, Overvoltage shutdown on output, Fan failure, Low voltage alarm, CAN bus failure |
Warnings (Yellow LED) | Rectifier in power derate mode, Remote battery current limit activated, Input voltage out of range, flashing at overvoltage |
Normal (Green LED) | Input and output ok |
MTBF (Telcordia SR-332 Issue I method III (a)) | >391 000h (@T AMBIENT= 25°C) |
Operating temperature (5 - 95% RH non-cond.) Output power de-rates above temp / to | -40 to +75°C [ -40 to +167°F] +55°C / 1350W @ +75°C |
Storage temperature | -40 to +85°C (-40 to +185°F), humidity 0 - 99% RH non-condensing |
Dimensions[WxHxD] / Weight | 109 x 41.5 x 327mm (WxHxD) [4.25 x 1.69 x 13"] / 1.950 kg [4.3lbs] |
DESIGN STANDARDS | |
Electrical safety | UL 60950 -1, EN 60950 -1, CSA 22.2 |
EMC | ETSI EN 300 386 V.1.3.2 EN 61000-6-1 / -2 / -3 / -4 / -5 |
Mains Harmonics | EN 61000 -3-2 |
Environment | ETSI EN 300 019: 2-1 (Class 1.2), 2-2 (Class 2.3) & 2-3 (Class 3.2) ETSI EN 300 132-2 2011/ 65/ EU (RoHS) & 2008/ 98/EC (WEEE) |
Marine compliance (EMC class B with AC filter) |
DnV Rules for Classification of Ships, High Speed & Light Craft and DnV Offshore Standards |
1 | Rectifier module | Emerson /Vertiv | R48-1800A | |
2 | Rectifier module | Emerson /Vertiv | R48-2000A3 | |
3 | Rectifier module | Emerson /Vertiv | R48-2900U | |
4 | Rectifier module | Emerson /Vertiv | R48-3000e3 | |
5 | Rectifier module | Emerson /Vertiv | R48-3500e | |
6 | Rectifier module | Emerson /Vertiv | R48-5800A | |
7 | Rectifier module | Huawi | R4850N1 | |
8 | Rectifier module | Huawi | R4850G1 | |
9 | Rectifier module | Eltek | Flatpack2 48/2000 HE 241115.105 |
|
10 | Rectifier module | Eltek | Flatpack2 48/1000 HE 241122.105 |
|
11 | Rectifier module | Eltek | Flatpack2 48/3000 HE 241119.105 |
|
12 | Rectifier module | Eaton | APR24-3G |