Customization: | Available |
---|---|
Type: | Wired |
Network Site: | Intermediate Node Routers |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
HW ME60 Series Multi-Service Control Gateways
#No | Part Number | Model | Description |
1 | ME0P08BASD75 | ME60-X8A Basic Configuration (Including ME60-X8A Chassis,2 SRUs,2 SFUs(480G),4 DC Power,2 Fan Tray, without Software Charge and Document) | |
2 | ME0P08BASA75 | ME60-X8A Basic Configuration (Including ME60-X8A Chassis,2 SRUs,2 SFUs(480G),6 AC Power,2 Fan Tray,without Software Charge and Document) | |
3 | ME0P08BASD77 | ME60-X8A Basic Configuration (Including ME60-X8A Chassis,2 SRUs,2 SFUs(480G),6 HVDC Power,2 Fan Tray, without Software Charge and Document) | |
4 | ME0P08BASD7D | ME60-X8A Basic Configuration (Including ME60-X8A Chassis,2 SRUs,2 SFUs(480G),4 DC Power,2 Fan Tray, without Software Charge and Document) | |
5 | ME0P08BASA7D | ME60-X8A Basic Configuration (Including ME60-X8A Chassis,2 SRUs,2 SFUs(480G),6 AC Power,2 Fan Tray,without Software Charge and Document) | |
6 | ME0P08BASH71 | ME60-X8A Basic Configuration (Including ME60-X8A Chassis,2 SRUs,2 SFUs(480G),6 HVDC Power,2 Fan Tray, without Software Charge and Document) | |
7 | ME0P08BASA7M | ME60-X8 Basic Configuration (Including ME60-X8 Chassis, 2+1 Redundant 200G SRU/SFU, 4 AC Power(Power Cords Cable), without Software Charge and Document) | |
8 | ME0P08BASA70 | ME60-X8 Basic Configuration (Including ME60-X8 Chassis, 2+1 200G Redundant SRU/SFUI-200-C, 4 AC Power, without Software Charge and Document) | |
9 | ME0P08BASD70 | ME60-X8 Basic Configuration (Including ME60-X8 Chassis, 2+1 200G Redundant SRU/SFUI-200-C, 4 DC Power, without Software Charge and Document) | |
10 | ME0P08BASD73 | ME60-X8 Basic Configuration (Including ME60-X8 Chassis, 2+1 Redundant 200G SRU/SFU, 4 DC Power, without Software Charge and Document) | |
11 | ME0P08BASA73 | ME60-X8 Basic Configuration (Including ME60-X8 Chassis, 2+1 Redundant 200G SRU/SFU, 4 AC Power, without Software Charge and Document) | |
12 | ME0P08BASA74 | ME60-X8 Basic Configuration (Including ME60-X8 Chassis, 2+1 Redundant 200G SRU/SFU, 4 AC Power(Power Cords Cable), without Software Charge and Document) | |
13 | ME0P08SFUE70 | ME60-X8 200G SFU Bundle Configuration(Including 2*SRUA5 and 1*SFUI-200-C) | |
14 | ME0P08SFUE71 | ME60-X8 200G Hardware Upgrade Bundle(Including 2*B5 SRUs,1*SFU) | |
15 | ME0P08BASA72 | ME60-X8 Basic Configuration (Including ME60-X8 Chassis. 2+1 Redundant 100G SRU/SFU. 4 AC Power. without Software Charge and Document) | |
16 | ME0P08BASD72 | ME60-X8 Basic Configuration (Including ME60-X8 Chassis. 2+1 Redundant 100G SRU/SFU. 4 DC Power. without Software Charge and Document) | |
17 | ME0P08BASA30 | ME60-X8 Basic Configuration (Including ME60-X8 Chassis.2+1 Redundant SRU/SFU.2 PFUs.4 AC Power.without Software Charge and Document) | |
18 | ME0P08BASD30 | ME60-X8 Basic Configuration (Including ME60-X8 Chassis.2+1 Redundant SRU/SFU.4 DC Power.without Software Charge and Document) | |
19 | ME0P08SFUF70 | ME60-X8 100G SFU Bundle Configuration(Including 2*SRUs.1*SFU) | |
20 | ME0P16BASA32 | ME60-X8 Basic Configuration (Including ME60-X8 Chassis.2+1 Redundant SRU/SFU.4 AC Power.without Software Charge and Document) | |
21 | ME0P16BASD32 | ME60-X8 Basic Configuration (Including ME60-X8 Chassis.2+1 Redundant SRU/SFU.4 DC Power.without Software Charge and Document) | |
22 | ME0B0BKP0871 | ME60-X8A Integrated Chassis DC Components(Including 2 Fan Tray) | |
23 | ME0B0BKP0872 | ME60-X8A Integrated Chassis AC Components(Including 2 Fan Tray) | |
24 | ME0B0BKP0873 | ME60-X8A Integrated Chassis HVDC Components (Including 2 Fan Tray) | |
25 | ME0D0SRUA470 | ME60-X8 Switch and Route Processing Unit A4 | |
26 | ME0DSFUI407C | ME60-X8 Switch Fabric Unit C | |
27 | ME0B0BKP0830 | ME60-X8 Integrated Chassis Components (Including 4 DC Power) |
The ME60 is a multi-service control gateway series launched by HW. ME60s are mainly used as broadband service access BRAS nodes and IP/MPLS network service-provisioning nodes.
The ME60 uses HW-developed Solar series NP chips. In addition, the ME60 uses the CLOS distributed multilevel switching architecture, and leverages distributed hardware-based forwarding and non-blocking switching to achieve excellent line-speed forwarding performance, superb scalability, comprehensive QoS, and strong service processing capabilities. Based on an industry-leading 2 Tbit/s platform, the ME60 is compatible with the line cards already installed on existing networks, which helps to maximize the protection of customer investment.
The ME60 is a high-performance service management and provisioning platform, which fully meets the requirements of a variety of service-provisioning modes, carries multiple services simultaneously, and ensures that a wide range of telecommunication services run stably and reliably. By using the ME60 and corresponding solutions, operators can construct a future-oriented intelligent broadband IP network with greatly reduced multi-service network construction and O&M costs.
The ME60 series includes the following models, which can meet the requirements of networks of various scales: ME60-X16A, ME60-X8A, ME60-X16, ME60-X8, and ME60-X3.
ME0P08BASA70 Specifications |
|
Switching Capacity |
12.58 Tbit/s |
Slots |
11 slots, including 2 SRUs (1:1 backup), 1 SFUs (2+1 backup), and 8 LPUs |
Dimensions (W x D x H) |
442 mm x 650 mm x 620 mm (14U) |
Maximum Power Consumption |
2,340W (120G) |
Full Configuration Weight |
119 kg (120G) |
Interface Types |
OC-192c/STM-64c POS OC-48c/STM-16c POS OC-3c/STM-1c POS OC-12c/STM-4c ATM OC-3c/STM-1c ATM 100GE-WAN/LAN 10GE-WAN/LAN GE/FE E3/CT3 CE1/CT1 |
BRAS |
User access protocol: PPPoE, PPPoEoA, IPoE, IPoEoA, and PPPoA 802.1X |
L2TP |
Session number: up to 64K/per slot, up to 128K/per chassis Tunnel number: up to 16K/per slot, up to 12K/per chassis |
IPv4 |
Static routing protocol and dynamic routing protocols such as RIP, OSFP, IS-IS, and BGP-4 |
IPv6 |
Various technologies for transition from IPv4 to IPv6: Manual tunnel configuration, automatic tunnel configurations, IPv6-to-IPv4(6-to-4) Tunneling, Generic Routing Encapsulation (GRE) tunneling, and Intra-Site Automatic Tunnel Addressing Protocol (ISATAP) tunneling IPv4 over IPv6 tunneling and IPv6 provider Edge Router (6PE). IPv6 static routing protocol IPv6 dynamic routing protocols such as RIP Next Generation (RIPng), OSPFv3, IS-ISv6, and BGP4+. IPv6 neighbor discovery and psth Maximum Transmission Unit (PMTU) discovery. Transmission Control Protocol Version 6(TCP6), ping IPv6, traceroute IPv6,socket IPv6, static IPv6 Domain Name System(DNS), specifying the IPv6 DNS server, Trivial File Transfer Protocol(TFTP) IPv6 dient, and IPv6 policy-based routing Internet Control Message Protocol Version 6(ICMPv6) Management Information Base (MIB),User Datagram Protocol Version 6(UDP6) MIB,ICP6 MIB, AND IPv6 MIB |
MPLS |
LDP over TE, VPLS, H-VPLS, policy-based routing inVPN. MPLS L2VPNs in either Martini or Kompella mode. VLL/VPLS access L3VPNs. QinQ, MPLS/BGP L3VPN, and inter-AS VPN Option A/B/C. Asynchronous Transfer Mode(ATM)E1, Inverse Multiplexing over ATM(IMA), and Time-Division Multiplexing(TDM)PWE3. MPLS-TP. |
Layer 2 feature |
IEEE802.1q, IEEE802.1p, IEEE802.3ad, and IEEE802.1ab. Spanning Tree Protocol(STP), Rapid Spanning Tree Protocol (RSTP),Multiple Spanning Tree Protocol (MSTP), RPPP, DHCP+ , VLAN switching, and user binding. |
QoS |
Weighted Random Early Detection (WRED), DS-TE capability with a maximum of eight CTs, five-level H-QoS scheduling, VLL/PWE3 QoS, and MPLS H-QoS. |
CGN |
NAT444,NAT64 Distributed deployment or integrated deployment Re-allocation or dynamic allocation of ports VPN NAT NAT ALG(TFP/ICMP/PPTP/RTSP/SIP) Port forwarding NAT server Web user's anthentication DS-Lite L2-Aware NAT |
DAA |
ME60s support Destination Address Accounting (DAA), providing refined subscriber management with differentiated service and accounting in IP networks. |