Customization: | Available |
---|---|
Phase: | Single Phase |
Type: | On-line |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Flexibility A UPS conquers a variety of installation environments and application scenarios
Flexible adaptability to environment and load
- ITA2 is compatible with input and output isolation transformers, input diesel generator and other designs.
- Based on the new system-level reliability design, ITA2, can be used in light industry, high altitude areas, ships, vehicles , beside traditional commercial use.
- 12-20 batteries adjustable (±12-20for 16/20K). compatible with lead acid, iron lithium, ni-cd batteries, etc.
- Tower and rack-mounted are supported. The height is only 2-3U.
ITA2 Typical Applicable Industries and Special Scenarios
New system-level reliability design
ITA2 is equipped with the latest generation of control chip. Control frequency and performance of the system are doubled.
ITA2 is designed with innovative "independent air flow channel" to isolate sensitive components, completely solving the UPS failures caused by dust and conductive powder and doubling the reliability of the system.
Excellent electrical performance ensures normal operation of the UPS for a long time.
ITA2 UPS passes rigorous test system and certification system.
Rigorous test system | |
Hygroscopic dust test | Seismic test |
High altitude test | Vehicle vibration test |
High and low temperature design margin test | Fire test |
Perfect certification system | |
CE | Energy Star |
TCL | Seismic technology certification |
CQC | Rohs |
Excellent electrical parameters
Output power factor of the whole series of ITA2 is increased to 1. KVA = KW. The load capacity is enhanced by 20%.
Input voltage range is improved to 100 - 288V, preventing the UPS from frequently switching to battery mode due to voltage fluctuation.
Overload capacity is improved to 150% , 1min, preventing the UPS from frequently switching to bypass mode due to short- time load impact.
System efficiency is increased to 96%, and energy saving rate doubled.
Charging capacity up to 13A (long back-up time model).
Power consumption | Cost (0.75 yuan/kWh) | Based on efficiency of 0.9 | Based on efficiency of 0.92 | Based on efficiency of 0.94 | |
0.96 | 6,570 | 4,928 | -8,212 | -5,356 | -2,621 |
0.95 | 8,299 | 6,224 | -6,916 | -4,059 | -1,324 |
0.94 | 10,065 | 7,549 | -5,591 | -2,735 | 0 |
0.93 | 11,868 | 8,901 | -4,239 | -1,382 | 1,353 |
0.92 | 13,711 | 10,283 | -2,857 | 0 | 2,735 |
0.91 | 15,595 | 11,696 | -1,444 | 1,413 | 4,148 |
0.9 | 17,520 | 13,140 | 0 | 2,857 | 5,591 |
Note: Take 20KVA / 18KW load for example. 8,212 yuan annually, 4.38 tons of standard coal combustionor10.95 tons of CO2 emissions is saved.
Excellent physical specifications
ITA2 volume is reduced by 30% than that of the previous generation of UPS, and weight reduced by 30%. It is smaller and more compact and can be easily installed and maintained on site by one person.
20KVA UPS is 500mm deep only, compatible with 800mm deep IT cabinet.
5-10KVA UPS is 2U (85mm) high, and 16-20KVA UPS is 3U (130mm) high only.
Innovation Leading the innovation
-TCP/IP & Dry contact is standard configuration, and can be connected to monitoring system (eg. RDU) easily.
- ITA2 is configured with large-size LCD display, which has the function of gravity self- adaption to automatically identify the UPS mounted way(tower /rack).
- The new "independent air flow channel" design can isolate sensitive components, completely solving the UPS failures caused by dust, conductive powder, etc.
- Programmable output terminals give longer back-up time for important devices.
- During configuration of the battery module, ITA2 can automatically identify the number of battery modules, while the battery backup time can be predicted, with prediction accuracy increased to be less than 10%.
Flexibility A UPS conquers a variety of installation environments and application scenarios
Flexible adaptability to environment and load
- ITA2 is compatible with input and output isolation transformers, input diesel generator and other designs.
- Based on the new system-level reliability design, ITA2, can be used in light industry, high altitude areas, ships, vehicles , beside traditional commercial use.
- 12-20 batteries adjustable (±12-20for 16/20K). compatible with lead acid, iron lithium, ni-cd batteries, etc.
- Tower and rack-mounted are supported. The height is only 2-3U.
Configuration Learn more about ITA2 for easy purchase. Options for ITA2 UPS
Name | Comment |
Options for battery | |
ITA BCI0020k02 | ITA2 5-20KVA UPS battery module with 16 12V9Ah batteries, 3U height, and support for tower /rack-mount |
ITA BCI0020k02L2 | Power cable between batterymodules |
ITA BCI0020k02L3 | Cable connecting battery modules with the UPS |
Monitoring Card | |
485 Card | Used in UPS to upload monitoring information through serial communication |
Temperature Sensor | With LCD display; used for UPS temperature compensation or access of RDU-SIC communication card |
Temperature and Humidity Sensor | With LCD display; used for UPS temperature compensation or access of RDU-SIC communication card |
POD | |
Standalone POD | UPS output distribution system with maintenance bypass |
1+1 parallel-system POD | UPS output distribution system with maintenance bypass, used for 1+1 parallel system. |
Monitoring Software | |
Network shutdown | Used for remote automatic shutdown of the server |
Options for system | |
Rall | Used for rack-mounting of UPS , battery module and POD |
Battery Backup Time Table (Battery Module)
Type | Number of BatteryModule | Backup Time | |||||||||
5kW | 4.5kW | 4kW | 3.5kW | 3kW | 2.5kW | 2kW | 1.5kW | 1kW | 0.5kW | ||
5kVA | 1 | 5.5 | 6.5 | 7.5 | 9.5 | 11.5 | 15.0 | 20.5 | 30.0 | 49.5 | 103.5 |
2 | 15.0 | 17.5 | 20.5 | 25.0 | 30.5 | 39.0 | 51.0 | 70.0 | 108.0 | 235.0 | |
3 | 27.0 | 31.0 | 36.0 | 42.5 | 51.0 | 63.0 | 80.5 | 110.0 | 177.0 | 368.5 | |
4 | 39.5 | 45.0 | 51.5 | 60.0 | 71.5 | 87.0 | 104.0 | 156.5 | 246.5 | 502.0 | |
5 | 51.5 | 58.0 | 66.5 | 77.0 | 91.5 | 111.5 | 146.0 | 203.5 | 316.0 | 635.5 | |
6 | 63.5 | 71.5 | 81.5 | 94.5 | 111.5 | 139.5 | 181.5 | 250.5 | 386.0 | 768.5 | |
Type | Number of BatteryModule | Backup Time | |||||||||
10kW | 9kW | 8kW | 7kW | 6kW | 5kW | 4kW | 3kW | 2kW | 1kW | ||
10kVA | 2 | 4.0 | 4.5 | 6.0 | 8.0 | 11.5 | 15.0 | 20.5 | 30.5 | 51.0 | 108.0 |
3 | 8.0 | 9.5 | 11.5 | 14.5 | 21.0 | 27.0 | 36.0 | 51.0 | 80.5 | 177.0 | |
4 | 12.5 | 15.0 | 18.0 | 22.0 | 31.0 | 39.5 | 51.5 | 71.5 | 110.5 | 246.5 | |
5 | 18.0 | 21.0 | 25.0 | 30.0 | 41.5 | 51.5 | 66.5 | 91.5 | 146.0 | 316.0 | |
6 | 23.5 | 27.0 | 32.0 | 38.5 | 51.5 | 63.5 | 81.5 | 111.5 | 181.5 | 386.0 | |
Type | Number of BatteryModule | Backup Time | |||||||||
16kW | 14.4kW | 12.8kW | 11.2kW | 9.6kW | 8kW | 6.4kW | 4.8kW | 3.2kW | 1.6kW | ||
16kVA | 4 | 7.5 | 9.0 | 10.5 | 13.0 | 16.0 | 21.0 | 28.5 | 41.5 | 66.5 | 145.0 |
6 | 14.0 | 16.0 | 19.0 | 24.5 | 28.5 | 36.5 | 48.0 | 66.5 | 104.0 | 233.5 | |
8 | 21.0 | 24.5 | 28.5 | 34.0 | 41.5 | 52.0 | 67.0 | 92.0 | 147.5 | 322.0 | |
10 | 28.5 | 33.0 | 38.5 | 45.5 | 54.5 | 67.0 | 86.0 | 118.5 | 192.5 | 410.5 | |
12 | 35.5 | 41.5 | 48.0 | 56.0 | 67.0 | 82.0 | 105.0 | 148.5 | 240.5 | 498.5 | |
Type | Number of BatteryModule | Backup Time | |||||||||
20kW | 18kW | 16kW | 14kW | 12kW | 10kW | 8kW | 6kW | 4kW | 2kW | ||
20kVA | 4 | 5.5 | 6.5 | 7.5 | 9.5 | 11.5 | 15.0 | 21.0 | 31.0 | 51.5 | 111.0 |
6 | 10.0 | 11.5 | 14.0 | 17.0 | 21.0 | 27.0 | 36.5 | 51.5 | 81.5 | 181.5 | |
8 | 15.0 | 17.5 | 21.0 | 25.5 | 31.0 | 39.5 | 52.0 | 72.0 | 112.0 | 252.5 | |
10 | 21.0 | 24.5 | 28.5 | 34.0 | 41.5 | 52.0 | 67.0 | 92.5 | 148.0 | 324.0 | |
12 | 27.0 | 31.5 | 36.5 | 43.0 | 52.0 | 64.0 | 82.0 | 112.5 | 184.0 | 395.0 |
Note: This table is for reference only. If high-capacity batteries are used externally, the capacity data will be different. Please consult your local dealer or contact Vertiv.
Specifications Learn more about ITA2 for easy purchase.
Capacity | 5/6KVA | 10KVA | 16/20KVA |
Input | |||
I/O mode | 1/1 | 1/1, 3/1 | 3/1, 3/3 |
Voltage Range | 100~288Vac | ||
Frequency Range | 40Hz~70Hz | ||
Current Harmonic | <5% | ||
Power Factor | 0.99 | ||
Battery - external | |||
Compatible Battery type | Lead acid, lithium, ni-cd | ||
Charger | < 5A (Long back-up model)< 2A (Standard model) | < 8A (Long back-up model)< 4A (Standard model) | < 13A (Long back-up model)< 5A (Standard model) |
Number of cell | 12/16/20 16 by default | ±12/±16/±20,±16 by default | |
Output | |||
Rated Power | 5KW/6KW | 10KW | 16KW/20KW |
Rated Voltage | 220/230/240 Vac | ||
Power Factor | 1 | ||
Voltage Stability | 1% | ||
Frequency Stability | ±0.1Hz | ||
Voltage harmonic distortion | < 2% (linear load); < 4% (non-linear load) | ||
Crest factor | 3:1 | ||
Dynamic voltage Transient range | 5% | ||
Voltage transient recovery time | 60ms | ||
Overload Capacity | 105%~125% load, 5min; 125%~150% load, 1min; >150% load, 200ms | ||
System | |||
Mounting | Tower/rack | ||
Efficiency | Up to 95.5% | Up to 95.8% | Up to 96% |
ECO Efficiency | 99% | 99% | 99% |
Number of units for parallel system | 4 at most | ||
Switching time (bypass to battery) | 0ms | ||
Switching time (inverter to bypass) | 0ms | ||
Noise | 55dB | 55dB | 58dB |
Protection Grade | IP20 | ||
Size (mm) | 430*85*400 | 430*85*500 | 430*130*500 |
Weight (Kg) | 11 | 15 | 23 |
Communication and management | |||
Interface Type | SNMP, USB, RS232, RJ45, dry contact, REPO, intelli-slot, parallel port | ||
Battery Temperature Sensor | Optional | ||
LCD | 2.8 inch color screen, gravity self-adaption, boot guide | ||
Environmental Parameter | |||
Operating Temperature | 0 ~ 50°C. Output power reduced to 70% in case of 50°C. | ||
Relative Humidity | 0~95% | ||
Max. Altitude Certification & Test |
3,000m. No deratingCE, Energy Star, TLC, CQC, seismic technology, shipping Rohs,Reach | ||
Wet dust test, fire test, temperature limit test, high altitude test, vehicle loading test |
Wuhan Unique Mechanical And Electrical Equipment Co., LTD. is a high-tech enterprises with a combination of of science, industry and trade. We mainly engaged in R&D and manufacturing of network center room equipment, such as PDU, ODF, CMA, Fiber Spool Frame, Network Panel, Network Cabinet, OF Jointing Box, Fiber Optic Connector, ADSS Cable, Micro Fiber, Pigtail, Patch Cord, UTP Cable, etc. Provide high level of technical consultation and technical services.