UPS Systems Vertiv (EMERSON) Liebrt Ita Series Ita2 5-20kVA

Product Details
Customization: Available
Phase: Single Phase
Type: On-line
Gold Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (16)
  • UPS Systems Vertiv (EMERSON) Liebrt Ita Series Ita2 5-20kVA
  • UPS Systems Vertiv (EMERSON) Liebrt Ita Series Ita2 5-20kVA
  • UPS Systems Vertiv (EMERSON) Liebrt Ita Series Ita2 5-20kVA
Find Similar Products

Basic Info.

Model NO.
LIEBRT ITA SERIES ITA2
Protection
Overvoltage
Application
Communication
Classification
Lighting/Power
Standby Time
Long-acting Machine
Standby UPS
Square Wave Output UPS
Output Capacity
Large Type
Equipment Mode
Decentralized
Brand
Emerson
Transport Package
Wooden Cases
Specification
Brand new
Trademark
Eaton
Origin
China
HS Code
8504402000
Production Capacity
1000set/Month

Product Description

Flexibility A UPS conquers a variety of installation environments and application scenarios

Flexible adaptability to environment and load

- ITA2 is compatible with input and output isolation transformers, input diesel generator and other designs.
- Based on the new system-level reliability design, ITA2, can be used in light industry, high altitude areas, ships, vehicles , beside traditional commercial use.
- 12-20 batteries adjustable (±12-20for 16/20K). compatible with lead acid, iron lithium, ni-cd batteries, etc.
- Tower and rack-mounted are supported. The height is only 2-3U.

ITA2 Typical Applicable Industries and Special Scenarios

Short Description:

New system-level reliability design

ITA2 is equipped with the latest generation of control chip. Control frequency and performance of the system are doubled.

ITA2 is designed with innovative "independent air flow channel" to isolate sensitive components, completely solving the UPS failures caused by dust and conductive powder and doubling the reliability of the system.

Excellent electrical performance ensures normal operation of the UPS for a long time.

ITA2 UPS passes rigorous test system and certification system.

UPS Systems Vertiv (EMERSON) Liebrt Ita Series Ita2 5-20kVA

Rigorous test system
Hygroscopic dust test Seismic test
High altitude test Vehicle vibration test
High and low temperature design margin test Fire test
Perfect certification system
CE Energy Star
TCL Seismic technology certification
CQC Rohs

Excellent electrical parameters

Output power factor of the whole series of ITA2 is increased to 1. KVA = KW. The load capacity is enhanced by 20%.
Input voltage range is improved to 100 - 288V, preventing the UPS from frequently switching to battery mode due to voltage fluctuation.
Overload capacity is improved to 150% , 1min, preventing the UPS from frequently switching to bypass mode due to short- time load impact.
System efficiency is increased to 96%, and energy saving rate doubled.
Charging capacity up to 13A (long back-up time model).

  Power consumption Cost (0.75 yuan/kWh) Based on efficiency of 0.9 Based on efficiency of 0.92 Based on efficiency of 0.94
0.96 6,570 4,928 -8,212 -5,356 -2,621
0.95 8,299 6,224 -6,916 -4,059 -1,324
0.94 10,065 7,549 -5,591 -2,735 0
0.93 11,868 8,901 -4,239 -1,382 1,353
0.92 13,711 10,283 -2,857 0 2,735
0.91 15,595 11,696 -1,444 1,413 4,148
0.9 17,520 13,140 0 2,857 5,591

Note: Take 20KVA / 18KW load for example. 8,212 yuan annually, 4.38 tons of standard coal combustionor10.95 tons of CO2 emissions is saved.

Excellent physical specifications

ITA2 volume is reduced by 30% than that of the previous generation of UPS, and weight reduced by 30%. It is smaller and more compact and can be easily installed and maintained on site by one person.
20KVA UPS is 500mm deep only, compatible with 800mm deep IT cabinet.
5-10KVA UPS is 2U (85mm) high, and 16-20KVA UPS is 3U (130mm) high only.
UPS Systems Vertiv (EMERSON) Liebrt Ita Series Ita2 5-20kVA

 

Innovation Leading the innovation

-TCP/IP & Dry contact is standard configuration, and can be connected to monitoring system (eg. RDU) easily.UPS Systems Vertiv (EMERSON) Liebrt Ita Series Ita2 5-20kVA
- ITA2 is  configured  with  large-size  LCD display, which has the function of gravity self- adaption to automatically identify the UPS mounted way(tower /rack).
UPS Systems Vertiv (EMERSON) Liebrt Ita Series Ita2 5-20kVA
- The new "independent air flow channel" design can isolate sensitive components, completely solving the UPS failures caused by dust, conductive powder, etc.
- Programmable output terminals give longer back-up time for important devices.
UPS Systems Vertiv (EMERSON) Liebrt Ita Series Ita2 5-20kVA
- During configuration of the battery module, ITA2 can automatically identify the number of battery modules, while the battery backup time can be predicted, with prediction accuracy increased to be less than 10%.
UPS Systems Vertiv (EMERSON) Liebrt Ita Series Ita2 5-20kVA

 

Flexibility A UPS conquers a variety of installation environments and application scenarios

Flexible adaptability to environment and load

- ITA2 is compatible with input and output isolation transformers, input diesel generator and other designs.
- Based on the new system-level reliability design, ITA2, can be used in light industry, high altitude areas, ships, vehicles , beside traditional commercial use.
- 12-20 batteries adjustable (±12-20for 16/20K). compatible with lead acid, iron lithium, ni-cd batteries, etc.
- Tower and rack-mounted are supported. The height is only 2-3U.

Configuration Learn more about ITA2 for easy purchase. Options for ITA2 UPS

Name Comment
Options for battery
ITA BCI0020k02 ITA2 5-20KVA UPS battery module with 16 12V9Ah batteries, 3U height, and support for tower /rack-mount
ITA BCI0020k02L2 Power cable between batterymodules
ITA BCI0020k02L3 Cable connecting battery modules with the UPS
Monitoring Card
485 Card Used in UPS to upload monitoring information through serial communication
Temperature Sensor With LCD display; used for UPS temperature compensation or access of RDU-SIC communication card
Temperature and Humidity Sensor With LCD display; used for UPS temperature compensation or access of RDU-SIC communication card
POD
Standalone POD UPS output distribution system with maintenance bypass
1+1 parallel-system POD UPS output distribution system with maintenance bypass, used for 1+1 parallel system.
Monitoring Software
Network shutdown Used for remote automatic shutdown of the server
Options for system 
Rall Used for rack-mounting of UPS , battery module and POD

Battery Backup Time Table (Battery Module)

Type Number of BatteryModule Backup Time
5kW 4.5kW 4kW 3.5kW 3kW 2.5kW 2kW 1.5kW 1kW 0.5kW
5kVA 1 5.5 6.5 7.5 9.5 11.5 15.0 20.5 30.0 49.5 103.5
2 15.0 17.5 20.5 25.0 30.5 39.0 51.0 70.0 108.0 235.0
3 27.0 31.0 36.0 42.5 51.0 63.0 80.5 110.0 177.0 368.5
4 39.5 45.0 51.5 60.0 71.5 87.0 104.0 156.5 246.5 502.0
5 51.5 58.0 66.5 77.0 91.5 111.5 146.0 203.5 316.0 635.5
6 63.5 71.5 81.5 94.5 111.5 139.5 181.5 250.5 386.0 768.5
Type Number of BatteryModule Backup Time
10kW 9kW 8kW 7kW 6kW 5kW 4kW 3kW 2kW 1kW
10kVA 2 4.0 4.5 6.0 8.0 11.5 15.0 20.5 30.5 51.0 108.0
3 8.0 9.5 11.5 14.5 21.0 27.0 36.0 51.0 80.5 177.0
4 12.5 15.0 18.0 22.0 31.0 39.5 51.5 71.5 110.5 246.5
5 18.0 21.0 25.0 30.0 41.5 51.5 66.5 91.5 146.0 316.0
6 23.5 27.0 32.0 38.5 51.5 63.5 81.5 111.5 181.5 386.0
Type Number of BatteryModule Backup Time
16kW 14.4kW 12.8kW 11.2kW 9.6kW 8kW 6.4kW 4.8kW 3.2kW 1.6kW
16kVA 4 7.5 9.0 10.5 13.0 16.0 21.0 28.5 41.5 66.5 145.0
6 14.0 16.0 19.0 24.5 28.5 36.5 48.0 66.5 104.0 233.5
8 21.0 24.5 28.5 34.0 41.5 52.0 67.0 92.0 147.5 322.0
10 28.5 33.0 38.5 45.5 54.5 67.0 86.0 118.5 192.5 410.5
12 35.5 41.5 48.0 56.0 67.0 82.0 105.0 148.5 240.5 498.5
Type Number of BatteryModule Backup Time
20kW 18kW 16kW 14kW 12kW 10kW 8kW 6kW 4kW 2kW
20kVA 4 5.5 6.5 7.5 9.5 11.5 15.0 21.0 31.0 51.5 111.0
6 10.0 11.5 14.0 17.0 21.0 27.0 36.5 51.5 81.5 181.5
8 15.0 17.5 21.0 25.5 31.0 39.5 52.0 72.0 112.0 252.5
10 21.0 24.5 28.5 34.0 41.5 52.0 67.0 92.5 148.0 324.0
12 27.0 31.5 36.5 43.0 52.0 64.0 82.0 112.5 184.0 395.0

Note: This table is for reference only. If high-capacity batteries are used externally, the capacity data will be different. Please consult your local dealer or contact Vertiv.

Specifications Learn more about ITA2 for easy purchase.

Capacity 5/6KVA 10KVA 16/20KVA
Input
I/O mode 1/1 1/1, 3/1 3/1, 3/3
Voltage Range 100~288Vac
Frequency Range 40Hz~70Hz
Current Harmonic <5%
Power Factor 0.99
Battery - external
Compatible Battery type Lead acid, lithium, ni-cd
Charger < 5A (Long back-up model)< 2A (Standard model) < 8A (Long back-up model)< 4A (Standard model) < 13A (Long back-up model)< 5A (Standard model)
Number of cell 12/16/20 16 by default ±12/±16/±20,±16 by default
Output
Rated Power 5KW/6KW 10KW 16KW/20KW
Rated Voltage 220/230/240 Vac
Power Factor 1
Voltage Stability 1%
Frequency Stability ±0.1Hz
Voltage harmonic distortion < 2% (linear load); < 4% (non-linear load)
Crest factor 3:1
Dynamic voltage Transient range 5%
Voltage transient recovery time 60ms
Overload Capacity 105%~125% load, 5min; 125%~150% load, 1min; >150% load, 200ms
System
Mounting Tower/rack
Efficiency Up to 95.5% Up to 95.8% Up to 96%
ECO Efficiency 99% 99% 99%
Number of units for parallel system 4 at most
Switching time (bypass to battery) 0ms
Switching time (inverter to bypass) 0ms
Noise 55dB 55dB 58dB
Protection Grade IP20
Size (mm) 430*85*400 430*85*500 430*130*500
Weight (Kg) 11 15 23
Communication and management
Interface Type SNMP, USB, RS232, RJ45, dry contact, REPO, intelli-slot, parallel port
Battery Temperature Sensor Optional
LCD 2.8 inch color screen, gravity self-adaption, boot guide
Environmental Parameter
Operating Temperature 0 ~ 50°C. Output power reduced to 70% in case of 50°C.
Relative Humidity 0~95%
Max. Altitude
Certification & Test
3,000m. No deratingCE, Energy Star, TLC, CQC, seismic technology, shipping Rohs,Reach
Wet dust test, fire test, temperature limit test, high altitude test, vehicle loading test

______________________________________________________

 

Wuhan Unique Mechanical And Electrical Equipment Co., LTD. is a high-tech enterprises with a combination of of science, industry and trade. We mainly engaged in R&D and manufacturing of network center room equipment, such as PDU, ODF, CMA, Fiber Spool Frame, Network Panel, Network Cabinet, OF Jointing Box, Fiber Optic Connector, ADSS Cable, Micro Fiber, Pigtail, Patch Cord, UTP Cable, etc. Provide high level of technical consultation and technical services.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.