• Zxdu58 W121 V4.0r01m08 Outdoor DC Power System Equipment
  • Zxdu58 W121 V4.0r01m08 Outdoor DC Power System Equipment

Zxdu58 W121 V4.0r01m08 Outdoor DC Power System Equipment

Output Type: Single
Warranty: 2 Years
Output Power: 1 - 50W
Input Voltage: Full Range
Connection Mode: Series Switching Power Supply
Starting Mode: Self-excited Switching Power Supply
Customization:
Gold Member Since 2020

Suppliers with verified business licenses

Rating: 5.0/5
Hubei, China
to see all verified strength labels (15)

Basic Info.

Model NO.
ZXDU58 W121
Voltage Regulating Mode
Frequency Modulation Type
Power Supplying System
Terminal Power Distribution Equipment
Energy Transmission
Two-way Transmission
Modulation System
PFAW
Certification
CE, UL, RoHS, ISO
Output Voltage
-53.5 V DC
Phase Voltage
220 V - 240 V
Line Vlotage
380 V - 415 V
Input Frequency
50 Hz / 60 Hz
Specification
Brand New
Origin
Wuhan, China
Production Capacity
1000 Sets/Month

Product Description

ZXDU58 W121 V4.0R01M08  Outdoor DC Power System For Communications Equipment

 

System introduction

 

The ZXDU58 W121 system is an outdoor DC power. It provides -53.5 V DC power for communications equipment.
AC input mode: Three-phase five-wire (L1/L2/L3/N/PE), 220 V - 240 V (phase voltage) / 380 V - 415 V (line voltage), 50 Hz / 60 Hz.
In full configuration, the ZXDU58 W121 system is equipped with four ZXD1500 rectifiers, which form a rated output current of 120 A.
For the ZXDU58 W121 system appearance, see Figure 1-1.

Zxdu58 W121 V4.0r01m08 Outdoor DC Power System Equipment
 

System features

 

The ZXDU58 W121 system has the following features:
*A wide range of input phase voltage (80 VAC - 300 VAC) makes the system suitable for areas with unstable voltage.
*Integrating the power distribution, rectifiers, CSU and batteries in a single cabinet, and thus saving installation space.
*The rectifier is hot-pluggable, and convenient for installation and maintenance.
*Intelligent CSU.
*With heat exchanger and Thermoelectric Cooler (TEC) for heat dissipation.
*High reliability with Mean Time Between Failures (MTBF) ≥ 2.2 × 105 h.
*Multiple networking interfaces: input relays, output relays, RS232 interfaces, and RS485 interface.

Zxdu58 W121 V4.0r01m08 Outdoor DC Power System Equipment
 

Item Description
Cabinet dimensions (H × W × D) Without thermoelectric cooler: 2200 mm × 700 mm × 700 mm
With thermoelectric cooler: 2200 mm × 700 mm × 850 mm
Communications equipment space 19 inches in width, 14U in height (1U = 44.45 mm)
Battery space (H × W × D) Two battery racks
Each rack provides a net installation space of 335 mm × 537 mm × 552 mm.
Dimension of the floor-mounting holes 8-Ø16 mm

 

Internal Structure


The internal space of the ZXDU58 W121 cabinet is divided into the equipment space and the battery space.
For the internal structure, see
For a description of the components, refer to Figure 2-2.

Zxdu58 W121 V4.0r01m08 Outdoor DC Power System Equipment
1. Heat exchanger
2. Thermoelectric cooler
3. Heater for battery space (optional)
4. Battery space
5. Power supply chassis
6. Signal Interface Board (SIB)
7. Communications equipment space
8. Ventilation subrack
9. Emergency light (optional)
10. Smoke sensor (optional)
11. Fan control board (FCTL)
12. PE busbar
13. Relay board (RLY)
14. Environment Monitoring Board (EMB)
15. Heater for equipment space (optional)
16. Internal cabling holes
17. External cabling holes
18. Door sensor
19. GND terminals

 

Table 2-2 Component Description

 

S.N. Component Description
1 Heat exchanger For heat dissipation of the equipment space
2 Thermoelectric cooler For heat dissipation of the battery space
3 Heater for battery space Optional, to heat the battery space if needed
4 Battery space Two battery racks. Each rack provides a net installation space of 335 mm × 537 mm × 552 mm (H × W × D)

 

S.N. Component Description
5 Power supply chassis Provides power input/output distribution and converts AC to DC
For the further details, refer to 2.3 Power Supply Chassis.
6 Signal Interface Board (SIB) Provides background communication interfaces and supervision interfaces
For the further details, refer to 2.6.1 Interface of SIB Board.
7 Communications equipment space Installs the communications equipment. 19 inches in width, and 14 U in height
8 Ventilation subrack For internal air circulation of the equipment space
9 Emergency light Optional, for emergency lighting
10 Smoke sensor Optional, for smoke detection
11 Fan control board (FCTL) Controls the operation of the fans in the heat exchanger and the ventilation subrack
12 PE busbar -
13 Relay board (RLY) Provides eight output relaysFor the further details, refer to 2.6.2 Interface of RLY Board.
14 Environment Monitoring Board (EMB) Provides environment monitoring interfacesFor the further details, refer to 2.6.3 Interface of EMB Board.
15 Heater for equipment space OptionalHeats the power & communications equipment space if needed
16 Internal cabling holes -
17 External cabling holes -
18 Door sensor For door status detection
19 GND terminals -


Power Supply Chassis


The power supply chassis provides power input/output distribution and converts AC to DC. For the layout of the components of the power supply chassis.

Zxdu58 W121 V4.0r01m08 Outdoor DC Power System Equipment
1. AC input circuit breaker
2. AC auxiliary output circuit breaker
3. AC SPD
4. DC output circuit breakers ( LLVD1)
5. DC output circuit breakers (LLVD2)
6. Battery input circuit breakers
7. DC Surge Protection Device (DC SPD)
8. Centralized Supervision Unit (CSU)
9. ZXD1500 rectifiers

 

For the internal structure of the power input/output distribution part

Zxdu58 W121 V4.0r01m08 Outdoor DC Power System Equipment

For a description of the components

 

S.N. Component Description
1 AC input circuit breaker Activates/deactivates AC input branch
2 AC auxiliary output circuit breaker Activates/deactivates AC auxiliary input branch Reserved for the heaters for the equipment space and the battery space
3 AC SPD Provides AC input surge protection
4 DC output circuit breakers ( LLVD1) Activate/deactivate DC output (LLVD1) branches
5 DC output circuit breakers (LLVD2) Activate/deactivate DC output (LLVD2) branches
6 Battery input circuit breakers Activate/deactivate battery input branches
7 DC Surge Protection Device (DC SPD) Provides DC output surge protection
8 Centralized Supervision Unit (CSU) Monitors the ZXDU58 W121 system
9 ZXD1500 rectifiers Convert AC to DC

2.2 ZXD1500 (V4.0) Rectifier
The ZXD1500 (V4.0) rectifiers convert AC to DC, provide power to the loads and charge the batteries.
Rectifier Appearance


For the appearance of a ZXD1500 (V4.0) rectifier, see Figure 2-5.

Zxdu58 W121 V4.0r01m08 Outdoor DC Power System Equipment
1. Indicators
2. Grille
3. Handle
4. Stop pin
5. Input/output integrated socket

Indicator Label Status and Color Meaning
IN(Input ) Lit (green) AC input power is normal.
OUT(Output) Lit (green) DC output power is normal.
CL(Current limit) Lit (yellow) Output current of the rectifier has reached its limit.
ALM(Alarm) Lit (red) An alarm has occurred.

Zxdu58 W121 V4.0r01m08 Outdoor DC Power System Equipment
 

Centralized Supervision Unit


The Centralized Supervision Unit (CSU) manages the power distribution unit, rectifiers and batteries of the ZXDU58 W121 system.

Functions

Collects the operational data and monitors the operation of the system.
Provides alarm and necessary protection if the system is operating abnormally.
Sends data to the background Supervision Center (SC) and receives the commands from the SC. In this way, the system can be monitored remotely.

Zxdu58 W121 V4.0r01m08 Outdoor DC Power System Equipment
1. Liquid Crystal Display (LCD)
2. Screen
3. Indicators
4. Reset button
5. Buttons
6. Handle
7. Power switch
8. Fastening screw
9. (Rear) Interface

 

Indicators


The indicators indicate the current operational status of the CSU. For a description of the CSU indicators.

Indicator Label Status and Color Meaning
PWR Power Lit (green) Power is applied to the CSU.
RUN Run Flashing (green) CSU is operating normally.
EQU Charge equalization Lit (green) Battery equalized charge is in-process.
COMM Communication Flashing (yellow) CSU is communicating with the connected PC.
ALM Alarm Flashing (red) An alarm or fault has occurred.

Zxdu58 W121 V4.0r01m08 Outdoor DC Power System Equipment
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now