• Eltek Flatpack2 Rectifier 48-60/2000 He Doc 241115.705. Ds3 - V9

Eltek Flatpack2 Rectifier 48-60/2000 He Doc 241115.705. Ds3 - V9

Usage: Telephone, Computer, Workstation, Server
Type: Wired
Support Network: Ethernet
Information content: Data
Certification: CE, ISO, RoHS
Condition: New
Customization:
Gold Member Since 2020

Suppliers with verified business licenses

Rating: 5.0/5
Hubei, China
to see all verified strength labels (15)

Basic Info.

Model NO.
241115.705
Dimensions
109 X 41.5 X 327mm
Weight
1.950 Kg (4.3lbs)
Transport Package
Carton Box
Specification
Brand New
Trademark
Eltek
Origin
Wuhan
Production Capacity
1000 Sets/Month

Product Description

Eltek Flatpack2 Rectifier 48-60/2000 HE Doc 241115.705.DS3 - v9

High efficiency and reliable rectifier/converter

The most efficient power conversion module in the industry! Since the launch the Flatpack 2 family has expanded into a wide selection of power ratings and voltages.
The Flatpack2 48-60/2000 HE is a cost efficient rectifier for 48V and 60V lead acid battery systems as well as 48V NiCad.

Applications

TELECOM
Radio base stations / Cell sites
LTE / 4G / WIMAX
Distributed  Antenna Systems
Microwave / Broadband
Central office
POWER UTILITIES
Control & protection
SCADA
Communications equipment
RAIL & METRO
Control & protection
Signaling
MARINE & OFFSHORE
Communications on ships

Key Features

High Efficiency -  96.2 %
Proven Reliability
High Power Density
Application Flexibility, 2kW To Multicabinet Installations
Modular Design
Mttr < 5mins
Accepts DC Input (DC/DC Converter)
Global Compliance (CE, Ul, NEBS)
Marine & Offshore Certifications
Patented Technology

Specifications
 
Model 48-60/2000 HE
Part number 241115.705
INPUT DATA  
Voltage (nominal) 185 - 275 VAC  / 185 - 275 VDC
Voltage (operating range) 85 - 300 VAC  / 80 - 300 VDC
Current (maximum) @ nominal input, full load 11.6 ARMS
Frequency 45 - 66 Hz / 0 Hz
Power Factor > 0.99 at 50% load or more
THD < 5% at 100% load
Protection Fuse in L & N, Varistor, Shutdown when input voltage is out of operating range
OUTPUT DATA  
Voltage (default) 1) 53.5 VDC   (67 VDC  in 60V mode)
Voltage (adjustable range) 1) 39.9 - 72 VDC
Power  (maximum) @ nominal input 2000 W (@VOUT  ≥ 48VDC)
Power @ 85 VAC 750 W
Current (maximum) @ nominal input 41.6 A (@VOUT  < 48VDC)
Hold up time, 1500W output power >20ms; output voltage > 53.5 VDC  (60V mode)
Current sharing (10 - 100% load) ±5% of maximum current from 10 to 100% load
Static Voltage regulation (10 - 100% load) ±0.5%
Dynamic Voltage regulation ±5.0% for 10-80% or 80-10% load variation, regulation time < 50ms
Ripple & noise < 150 mVPP , 30 MHz bandwidth / < 2 mVRMS psophometric
Protection Fuse , Short circuit proof, High temperature protection, Over voltage Shutdown
OTHER SPECIFICATIONS  
Efficiency 96.2 %
Isolation 3.0 kVAC  - input to output, 1.5 kVAC  - input to earth, 500 VDC  - output to earth
  Low / high input voltage shutdown, High / low temperature shutdown, Rectifier
Alarms: Red LED Failure, Overvoltage shutdown on output, Fan failure, Low output voltage
alarm, CAN bus failure
Rectifier in power de-rate mode,  Remote output current limit activated, Input
   
Warnings: Yellow LED voltage out of range, flashing at overvoltage, Loss of CAN communication with controller
Normal operation: Green LED  
MTBF (Telcordia SR-332 Iss.I method III (a)) >350 000 (@ Tambient  : 25 °C)
Operating temp. (5-95% RH n.cond. hum.) -40 to + 75°C [-40 to +167°F]
Max output power de-rates above temp / to 45°C [113°F] / 1200W @ 75°C[167°F]
Storage temperature -40 to +85°C (-40 to +185°F),  humidity 0 - 99% RH non-condensing
Dimensions[WxHxD] / Weight 109 x 41.5 x 327mm (4.25 x 1.69 x 13") / 1.950 kg (4.3lbs)
DESIGN STANDARDS  
Electrical safety EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013, IEC 60950-1:2013 UL 60950-1:2011
EMC EN 61000-6-1:2007, -6-2:2005, -6-3:2007 + A1:2011, -6-4:2007 + A1:2011,
IEC 61000-6-5: 2015, ETSI EN 300 386:2.1.1
Marine DNVGL-CG-03392)
Environment ETSI EN 300 019: 2-1 (Class 1.2) & 2-2 (Class 2.3)
2011/65/EU (RoHS) & 2012/19/EU (WEEE)
Normal operating conditions as per IEC 62040-5-3:2016 clause 4.2. Other
operating conditions as per IEC 62040-5-3:2016 clause 4.3, must be advised
OVS setting from controller select mode: OVS≤59.5V = 48V mode (42-58V), 59.5V<OVS<70.85 = 48V NiCad mode (39.9-66V) and OVS≥70.85V = 60V mode (52.5-72V). W hen de-energized module will return to 48V mode.
Only valid for part number 241115.705M

Hotsale Modules

1 Rectifier module Emerson /Vertiv R48-1800A Eltek Flatpack2 Rectifier 48-60/2000 He Doc 241115.705. Ds3 - V9
2 Rectifier module Emerson /Vertiv R48-2000A3 Eltek Flatpack2 Rectifier 48-60/2000 He Doc 241115.705. Ds3 - V9
3 Rectifier module Emerson /Vertiv R48-2900U Eltek Flatpack2 Rectifier 48-60/2000 He Doc 241115.705. Ds3 - V9
4 Rectifier module Emerson /Vertiv R48-3000e3 Eltek Flatpack2 Rectifier 48-60/2000 He Doc 241115.705. Ds3 - V9
5 Rectifier module Emerson /Vertiv R48-3500e Eltek Flatpack2 Rectifier 48-60/2000 He Doc 241115.705. Ds3 - V9
6 Rectifier module Emerson /Vertiv R48-5800A Eltek Flatpack2 Rectifier 48-60/2000 He Doc 241115.705. Ds3 - V9
7 Rectifier module Huawi R4850N1 Eltek Flatpack2 Rectifier 48-60/2000 He Doc 241115.705. Ds3 - V9
8 Rectifier module Huawi R4850G1 Eltek Flatpack2 Rectifier 48-60/2000 He Doc 241115.705. Ds3 - V9
9 Rectifier module Eltek Flatpack2 48/2000 HE
241115.105
Eltek Flatpack2 Rectifier 48-60/2000 He Doc 241115.705. Ds3 - V9
10 Rectifier module Eltek Flatpack2 48/1000 HE
241122.105
Eltek Flatpack2 Rectifier 48-60/2000 He Doc 241115.705. Ds3 - V9
11 Rectifier module Eltek Flatpack2 48/3000 HE
241119.105
Eltek Flatpack2 Rectifier 48-60/2000 He Doc 241115.705. Ds3 - V9
12 Rectifier module Eaton APR24-3G Eltek Flatpack2 Rectifier 48-60/2000 He Doc 241115.705. Ds3 - V9

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now