UPS2000-A series (6-10kVA) is a tower-mounted, online double conversion power system that delivers continuous, high-quality AC Power. up to 96% efficiency at online mode for 6/10kVA models helps save 50% energy cost. It's really a perfect power protection solution for small power scenarios.
Scenarios
• Small and medium enterprises, large enterprise branch offices, bank branches and other small data centers.
• Networks, communications systems, automatic control systems and other precision equipment.
• Family, office.
Features
Reliable
Wide input voltage range to minimize battery use.
Key component failure pre-alarm including fans, batteries to remind customers to maintain before failure occurs.
Coating design & key device pin special protection enhance reliability.
Efficient
High efficiency of up to 96% at online mode for 6/10kVA reduces power loss of UPS and air conditioner and saves customers more than 50% over less efficient models.
The output power factor is 0.9, high load capacity.
Simple
LCD screen supports real-time monitoring and convenient operation.
The NetEco 1000U management system monitors UPSs in real time and allows users easy management, and operation.
Multiple remote monitoring: supports SMS, E-mail, etc.
Specifications
Rated capacity (kVA/kW) | 6kVA/5.4kW | 10kVA/9kW | ||
Model | UPS2000-A-6KTTL-S | UPS2000-A-10KTTL-S | ||
Input: Output | 1 phase input, 1 phase output | |||
Mains | Input Wiring | L+N+PE | ||
Rated Input Voltage | 220/230/240V AC | |||
Input Voltage Range | 80-280V AC | |||
Input Frequency Range | 50/60Hz ± 5Hz | |||
Input power factor | ≥ 0.99 | |||
Total Harmonic Distortion | Total Harmonic Distortion of current <3% at rated load | |||
Bypass Input | Input rated voltage | 220/230/240V AC | ||
Input frequency range | 50/60Hz ± 5Hz | |||
Battery | Battery voltage | Long backup | 192-240V DC | 192-240V DC |
Output | Output wiring | L+N+PE | ||
Rated voltage | 220/230/240V AC ±1% | |||
Output frequency | Tracking the bypass input (Normal mode); 50/60Hz ± 0.05% (Battery Mode) | |||
Output power factor | 0.9 | |||
Waveform | Sine wave, THDv ≤ 2% | |||
System | Efficiency | Up to 96% | ||
Overload capacity | ≤125% overload for 5 minutes; ≤150% overload for 1 minute | |||
Enviro-nment | Operating Temperature | 0°C to 40°C | ||
Relative Humidity | 0%-95% RH (no condensation) | |||
Altitude | 0-1000m. Above 1000m, derating rate based on EN/IEC 62040-3 | |||
Audible Noise | <50dB | |||
Others | Height×Width×Depth (mm) | 580 x 250 x 605 | ||
Weight | Long backup | 20kg | 21kg | |
Certifications | EN/IEC 62040-1; EN/IEC 62040-2; EN/IEC 62040-3; CE; CB; RoHS, REACH, WEEE, etc. | |||
Communications | USB (optional RS485/Dry contact/SNMP) |
Models for 1-10KVA UPS
Model | Descriptions | Battery Request (12V) | Install Way |
UPS2000-A-1KTTS | Built-in battery, backup time 4 mins on full load | Tower Mounted | |
UPS2000-A-1KTTL | Without built-in battery,shall equip with external battery | 3PCS | |
UPS2000-A-2KTTS | Built-in battery, backup time 4 mins on full load | ||
UPS2000-A-2KTTL | Without built-in battery,shall equip with external battery | 6PCS | |
UPS2000-A-3KTTS | Built-in battery, backup time 4 mins on full load | ||
UPS2000-A-3KTTL | Without built-in battery,shall equip with external battery | 8PCS | |
UPS2000-A-6KTTL-S | Without built-in battery,shall equip with external battery | 16-20 PCS | |
UPS2000-A-10KTTL-S | Without built-in battery,shall equip with external battery | 16-20PCS |