Customization: | Available |
---|---|
Phase: | Single Phase |
Type: | On-line |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Short Description:
Features
* Online double conversion design, ensuring reliable power supply;
* Extra wide input voltage/frequency range, adaptable to bad mains environment;
* Large LCD display, obtaining operating status more directly;
* High density design, dimensions smaller than competitive product by 20%~40%;
* Excellent environment protection and energy saving characteristic with up to 91% efficiency;
* Rich monitoring management software, improving system reliability.
Applications
Servers, memory, network support equipment, VoIP, communication devices, automatic control equipment, precision instruments, medical equipment, Office terminals, switch and server between networks and small IDC rooms.
Applicable industries
Telecom, finance, government, medical, education, manufacturing, post service/ logistics, transportation/retail sales.
Product
Parameters
Parameters | Model | ||
GXE 06k00TE1101C00/ GXE 06k00TL1101C00 | GXE 10k00TE1101C00/ GXE 10k00TL1101C00 | ||
Capacity/power level | 6000VA/4800W | 10000VA/8000W | |
Input parameters | Voltage range | 120Vac~288Vac, 176-288Vac full load operation; 120-176Vac linear derating | |
Rated voltage | 220/230/240Vac | ||
Power factor | ≥0.99 | ||
Frequency | 50Hz/60Hz±5Hz | ||
Output | voltage | 220/230/240Vac±3% | |
Power factor | 0.8 | ||
Frequency | In normal mode and when bypass is within the range of 50Hz/60Hz±5Hz, the output tracks the bypass frequency | ||
Waveform | Sine-wave | ||
Load crest factor | 3:1 | ||
Output voltage THD | ≤3% for linear load, ≤5% for non-linear load | ||
Overload performance | Rated input: 105~125%, 5min | ||
Efficiency at utility mode | 91% | ||
Battery | type | Valve regulated lead-acid maintenance-free battery | |
Quantity * voltage * capacity | 16X12VX7Ah (battery module of standard unit); Dependent on the external batteries (unit with long backup time) | ||
Rated voltage | 192Vdc | ||
Charging current | Standard unit: 2Amax: Unit with long backup time: 4A max | ||
Re-charge time | With 100% load, discharging until UPS shuts down automatically, and charging to 90% battery capacity for 6 hours (only for standard unit) | ||
Environment | Operating temperature | 0°C~+40°C | |
Storage temperature | -40°C~+70°C | ||
Relative humidity | 5%RH~95%RH, no condensation | ||
Elevation | <1500m, derated according to GB/T3859.2 if higher than 1500m | ||
Noise | <55dB | <58dB | |
Communication and management | Communication interface | DB-9 RS-232, B type USB | |
Installation mode | Tower type | ||
Transfer time | Utility--battery 0ms | ||
Safety | CCEE (GB4943-1995)/GB4943 | ||
EMC | CE/RE | IEC/EN/AS 62040-2 2nd Ed =CISPR22 Class A | |
surge | IEC/EN 61000-4-5, Level 4 (4kV) (between hot line and ground), Level 3 (2kV) (between hot lines) | ||
Dimensions (H x W x D) (mm) | Unit without embedded software | 180×345×525 | 180×455×525 |
Battery box module | 180×345×525 | ||
Weight (kg) | Unit without embedded software | 16.5 (standard unit)/17 (unit with long backup time) | 22.8 (standard unit)/23 (unit with long backup time) |
Battery box module | 58 | ||
Color | Black RAL7021 |
Optional spare parts
Optional part of communication card | Description |
RDU-SIC card | Monitor the status of intelligent device, record alarm event and notify user via Email or short message, and set operating parameters and query equipment status via embedded web Pages, and send the status of monitoring device to the network management software via SNMP protocol. Network management software |
MODBUS card | Used when UPS is connected in a building monitoring system |
RS-485 card | RS485 card can realize the conversion of RS232 signal to RS485 signal, and is used in the connection between UPS and Emerson RDU-A intelligent room monitoring unit |
Dry contact card | Providing 4 relay outputs and 3 digital inputs |
Dry contact extension card | Providing 4 relay outputs and 3 digital inputs, as well as the RS232 and RS485 communication functions, and providing 4 analog value sampling functions Data acquisition function |
Long back up time for reference
Number of battery box module | Load | |||||
8000W | 7000W | 4800W | 3000W | 2000W | 1400W | |
1 | - | - | 4.2m | 6.7m | 25m | 45.8m |
2 | 6m | 8m | 9.2m | 13.3m | 55m | 1h20m |
3 | 13m | 17m | 20m | 28.3m | 1h30m | 2h25m |
4 | 20m | 23m | 30m | 38.3m | 1h50m | 3h19m |
5 | 23m | 26m | 35m | 48.3m | 2h14m | 3h33m |
6 | 26m | 33m | 40m | 55m | 2h48m | 3h49m |
7 | 28m | 35m | 44m | 58.3m | 2h50m | 4h |
8 | 38m | 50m | 58m | 83.3m | 2h55m | 4h15m |
9 | 46m | 55m | 1h10m | 1h32m | 3h25m | 4h55m |
10 | 55m | 1h7m | 1h23m | 1h57m | 3h55m | 5h40m |
Remarks:Upgrade GXE2 also exist.
Wuhan Unique Mechanical And Electrical Equipment Co., LTD. is a high-tech enterprises with a combination of of science, industry and trade. We mainly engaged in R&D and manufacturing of network center room equipment, such as PDU, ODF, CMA, Fiber Spool Frame, Network Panel, Network Cabinet, OF Jointing Box, Fiber Optic Connector, ADSS Cable, Micro Fiber, Pigtail, Patch Cord, UTP Cable, etc. Provide high level of technical consultation and technical services.